Meilink Safes
a member of FireKing Security Group
FireKing Security Group
Meilink Products Resource Center Meilink Safes

Options

The number of adjustable shelves provided with each depends on the dimensions of the safe. Additional shelves are available for all safe models. The standard safe color is graphite. Taupe is an optional color for several models. Dial combination locks are standard on all models. Upgrades to dial combination locks, including spyproof rings, locking rings, and keyed daylock features are available on several models. Digital combination locks are available for most models.
 
 

Ratings

A wide variety of models are available depending on the combination of fire and theft resistance required. The chart below should help you determine which model will best meet your needs:

Model
Fire Rating
Burglary Rating
1/2 Hour Fire
Unrated
1 Hour Fire
Unrated
2 Hour Fire & Impact
Unrated
1 Hour Fire
RSC
1 or 2 Hour Fire & Impact
RSC
1/2 Hour Fire
C-Rate
1 Hour Fire
TL-15/30/30x6


UL Class-350 1/2 Hour Fire Rating: The safe is tested for 1/2 hour in a furnace with temperatures rising to 1700°F. The internal temperature of the safe must remain below 350°F for the duration of the test.

UL Class-350 1 Hour Fire Rating: The safe is tested for 1 hour in a furnace with temperatures rising to 1700°F. The internal temperature of the safe must remain below 350°F for the duration of the test.

UL Class-350 2 Hour Fire Rating: The safe is tested for 2 hours in a furnace with temperatures rising to 1850°F. The internal temperature of the safe must remain below 350°F for the duration of the test.

Omega Point 1 Hour Fire Rating (Gibralter Only): The safe is tested for 1 hour in a furnace with temperatures rising to 1700°F. The internal temperature of the safe must not rise more than 275°F for the duration of the test.

UL Impact Test (for 1-Hour Fire Rating): The safe is heated to 1550°F for 30 minutes then dropped onto concrete rubble from a height of 30 feet. It is then inverted and reheated 30 more minutes. The safe must maintain its integrity and protect its contents for the duration of the test.

UL Impact Test (for 2-Hour Fire Rating): The safe is heated to 1638°F for 45 minutes then dropped onto concrete rubble from a height of 30 feet. It is then inverted and reheated 45 more minutes. The safe must maintain its integrity and protect its contents for the duration of the test.

UL RSC Rating: The safe must be meet specific construction requirements. The safe is also tested to prevent access to contents by physical attack using specific common burglary tools for a period of at least 5 minutes.

UL TL (Tool Attack) Rating: The safe must be meet specific construction requirements. The safe is also tested to prevent access to contents by physical attack using specific tools including grinders, pick axe, sledge hammer, drills, and saws for a specified period. TL-15 means it passed a 15-man-minute test. TL-30 means it passed a 30-man-minute test. TL-30x6 means it must pass additional tests and added construction requirements on all six sides.